REVO 80
OCT made simple as never before
Position the patient and press the START button to acquire examinations of both eyes. The Revo 80, guides the patient through the process with vocal messages to increase comfort and reduce patient chair time.
Our supreme experience in Spectral Domain OCT allows us to provide the market with a state of the art instrument which comes with new advanced technologies and remarkable simplicity of operation. The REVO 80 will expand the daily demands of any modern practice.
A perfect fit for every practice.
Small system footprint, various operator and patient positions and connection by a single cable allows the installation of REVO 80 into the smallest of examination room spaces. With its variety of examination and analysis tools, the REVO can easily function as a screening or advanced diagnostic device.
New OCT standard – All functionality In One device.
Once again REVO goes beyond the limits of standard OCT. With its new software, the device provides a full functionality from the retina to the cornea to combine the potential of several devices. With REVO you can measure, quantify, calculate and track changes from the cornea to the retina over time with just one OCT device.
Specifikationer
Technology |
Spectral Domain OCT
|
|
Scanning speed | 80 000 measurements per second | |
Light Source |
SLED, Wavelength 850 nm
|
|
Bandwidth |
50 nm half bandwidth
|
|
Axial resolution |
2.6 μm digital, 5 μm in tissue
|
|
Transverse Resolution |
12 μm, typical 18 μm
|
|
Overall scan depth |
2.8 mm / ~6 mm in Full Range mode
|
|
Scan range |
Posterior 5 mm to 15 mm, Angio 3 mm to 6 mm, Anterior 3 mm to 18 mm
|
|
Scan program | 3D, Angio, Full Range Radial, Full Range B-scan, Radial, B-scan, Raster, Cross, TOPO, AL, ACD | |
Fundus image |
Live Fundus Reconstruction
|
|
Alignment method |
Fully automatic, Automatic, Manual
|
|
Retina analysis |
Retina thickness, Inner Retinal thickness, Outer Retinal thickness, RNFL+GCL+IPL thickness, GCL+IPL thickness, RNFL thickness, RPE deformation, MZ/EZ-RPE thickness
|
|
Angiography OCT available only for SOCT Copernicus REVO with 80 000 and 60 000 measurements per secondAngiography mosaic |
Vitreous, Retina, Choroid, Superficial Plexus, RPCP, Deep Plexus, Outer Retina, Choriocapilaries, Depth Coded, SVC, DVC, ICP, DCP, Custom, Enface, FAZ, VFA, NFA, Quantification: Vessel Area Density, Skeleton Area Density, Thickness map
Acquistion method: Auto, Manual |
|
Glaucoma analysis |
RNFL, ONH morphology, DDLS, OU and Hemisphere asymmetry, Ganglion analysis as RNFL+GCL+IP and GCL+IPL,
Structure + Functionvia connection with PTS software version 3.4 or higher |
|
Anterior |
Pachymetry, Epithelium map, Stroma map, AIOP, Angle Assessment, AOD 500/750, TISA 500/750
|
|
Anterior (no lens/adapter required) |
Anterior Chamber Radial, Anterior Chamber B-scan, Angle to Angle view
|
|
Biometry OCT an optional software module to purchase |
AL, CCT, ACD, LT, P, WTW IOL Formulas: Hoffer Q, Holladay I, Haigis, Theoretical T, Regression II |
|
Corneal Topography Map an optional software module to purchase for SOCT Copernicus REVO with 80 000 and 60 000 measurements per second |
Axial [Anterior, Posterior], Refractive Power [Kerato, Anterior, Posterior, Total], Net Map, Axial True Net, Equivalent Keratometer, Elevation [Anterior, Posterior], Height, KPI (Keratoconus Prediction Index) | |
Connectivity | DICOM Storage SCU, DICOM MWL SCU, CMDL, Networking | |
Minimum pupil size
|
2.4 mm | |
Focus adjustment range |
-25 D to +25 D
|
|
Dimensions (W×D×H)
|
|
|
Weight |
29 kg
|
|
Fixation target |
OLED display (The target shape and position can be changed),
External fixation arm |
|
Power supply |
100–240 V, 60/50 Hz
|
|
Power consumption |
90–110 VA
|